HBUS Modules and IO Devices

Flexible, fast, cost-effective and secure, Gallagher HBUS I/O Devices provide input and output expansion options, extending the connectivity of the Gallagher Controller 6000 and supporting shared cabling with other HBUS devices.

Technical spec sheets

    Features and benefits

    • High speed communication – the HBUS communication protocol is based on the RS485 standard, delivering high speed communication between each HBUS I/O Device and the Gallagher Controller 6000 at a rate of 1Mb/s over a distance of up to 500m (1640 ft.).
    • Automated device software upgrades – HBUS I/O Device software is automatically available with Controller 6000 software upgrades, meaning no operator intervention is required.
    • Tamper protection – IT-grade authentication and encryption prevents data tampering and further enhances the security of your system.
    • Unique identities for all field devices – ensures compromised devices cannot be added to the system.
    • Variable end-of-line resistance – allows Gallagher HBUS devices to be easily installed using a site’s existing security wiring.

    HBUS Modules

    Gallagher 8H and 4H modules support star wiring of secure high-speed HBUS devices including T Series Readers and the F22 Fence Controller to a secure Gallagher Cabinet. Star wiring HBUS devices to a controller cabinet removes the risk of one faulty connection taking down multiple devices, and enables easier fault isolation. I/O connectivity is also provided for door and equipment monitoring.

    Gallagher HBUS Modules are:

    • 8H Module provides 8 HBUS ports, 24 balanced inputs and 8 relay outputs
    • 4H Module provides 4 HBUS ports, 12 balanced inputs and 4 relay outputs.

    HBUS I/O Devices

    Gallagher HBUS I/O Devices provide flexible, cost effective and secure input and output expansion options, and shared cabling with other HBUS devices.

    The Gallagher 8 In 2 Out Door Module:

    • connects reader or terminal devices up to 400m (1312ft.) away allowing HBUS communications to be branched or 'T' Wired from HBUS cabling connected to the Controller 6000
    • provides isolation between its upstream and downstream HBUS runs protecting other HBUS Devices connected to the same controller HBUS port
    • provides connections for Gallagher's T Series Reader range.

    The Gallagher HBUS 4 In 2 Out Door Module – Wiegand provides connection for two Wiegand readers, 4 balanced inputs and 2 relay outputs.

    The Gallagher HBUS I/O Board are:

    • 16 In 16 Out Board
    • 8 In 4 Out Board
    • 8 In Board.

    Monitoring inputs may be used for monitoring:

    • access controlled doors
    • passive Infrared detectors (PIRs)
    • uncontrolled doors
    • equipment alarms
    • any other devices that provide a clean contact.

    Activating outputs - relays may be used as:

    • door control
    • alarm output for example activating sirens
    • logic activated output for example switching air conditioning on and off
    • time activated output for example switching lighting on and off.

    Related Products

    X
    Cookies help us improve your website experience.
    By using our website, you agree to our use of cookies.
    Confirm